Patient radiation dose from chest x-ray examinations in the west bank—Palestine

dc.contributor.authorLahham, Adnan
dc.contributor.authorIssa, Ahlam
dc.contributor.authorALMasri, Hussein
dc.date.accessioned2019-03-31T14:43:16Z
dc.date.available2019-03-31T14:43:16Z
dc.date.issued2017-08-30
dc.description.abstractRadiation doses to patients resulting from chest X-ray examinations were evaluated in four medical centers in the West Bank and East Jerusalem—Palestine. Absorbed organ and effective doses were calculated for a total of 428 adult male and female patients by using commercially available Monte Carlo based softwares; CALDOSE-X5 and PCXMC-2.0, and hermaphrodite mathematical adult phantoms. Patients were selected randomly from medical records in the time period from November 2014 to February 2015. A database of surveyed patients and exposure factors has been established and includes: patient’s height, weight, age, gender, X-ray tube voltage, electric current (mAs), examination projection (anterior posterior (AP), posterior anterior (PA), lateral), X-ray tube filtration thickness in each X-ray equipment, anode angle, focus to skin distance and X-ray beam size. The average absorbed doses in the whole body from different projections were: 0.06, 0.07 and 0.11 mGy from AP, PA and lateral projections, respectively. The average effective dose for all surveyed patients was 0.14 mSv for all chest X-ray examinations and projections in the four investigated medical centers. The effect of projection geometry was also investigated. The average effective doses for AP, PA and lateral projections were 0.14, 0.07 and 0.22 mSv, respectively. The collective effective dose estimated for the exposed population was ~60 man-mSv.en_US
dc.description.sponsorshipAuthors would like to thank administrative and other personnel working at the investigated medical centers for facilitating our research and providing all means of help and support and for supplying all required data.en_US
dc.identifier.issn1742-3406
dc.identifier.urihttps://dspace.alquds.edu/handle/20.500.12213/4777
dc.language.isoenen_US
dc.publisherOxford University Press.en_US
dc.titlePatient radiation dose from chest x-ray examinations in the west bank—Palestineen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Paper chest X-ray.pdf
Size:
295.24 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: