Marginal and Internal Crown Fit Evaluation of CAD/CAM versus Press-Laboratory Lithium Disilicate Crown

dc.contributor.authorMusleh, Ayman
dc.date.accessioned2020-10-14T06:25:43Z
dc.date.available2020-10-14T06:25:43Z
dc.date.issued2019-09-10
dc.description.abstractThis study aims to evaluate the marginal gap and internal adaptation of lithium disilicate crowns fabricated by conventional press-dental laboratory and CAD/CAM systems. The size of the marginal and internal gaps of crowns is fabricated with the two techniques in the current study; the research will be performed in an effort to improve clinical outcomes. Tooth #14 was prepared per standard specification to receive the lithium disilicate crowns. Sixty Type IV gypsum dies tooth #14 were duplicated and divided into three groups (n=30). The lithium disilicate CAD/CAM system (Group 1) was fabricated with the E4D CAD/CAM system according to manufacturer's instructions. For press-dental laboratory made crowns, impressions were taken on the region area with two-step impression techniques with light and putty consistency VPS. Impressions were sent to two independent dental laboratories (Groups 2 and 3) for fabricating the monolithic press lithium disilicate crown. Tooth #14 was optically scanned and lithium disilicate blocks were used to fabricate crowns using CAD/CAM technique. Polyvinyl siloxane impressions of the prepared teeth were made and monolithic pressed lithium disilicate crowns were fabricated. The marginal gap was measured using optical microscope at 160× magnification (Keyence VHX-5000, Japan) and internal fit of the crowns was assessed by the silicone replica technique. Four sections of each replica were obtained, and each section was evaluated at four points: marginal gap (MG), axial wall (AW), axio-occlusal edge (AO) and Centro-occlusal wall (CO), using an image analyzing software. Statistical analysis was performed using ANOVA and chi-squared test. Study design: Experimental. Setting of study: University of Palestine and Laser Specialized center For Esthetic Dentistry.en_US
dc.identifier.urihttps://dspace.alquds.edu/handle/20.500.12213/6211
dc.language.isoenen_US
dc.publisherAl-Quds University, Deanship of Scientific Researchen_US
dc.titleMarginal and Internal Crown Fit Evaluation of CAD/CAM versus Press-Laboratory Lithium Disilicate Crownen_US
dc.typeArticleen_US
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Marginal and Internal Crown Fit Evaluation of CAD-CAM versus Press-Laboratory Lithium Disilicate Crown..pdf
Size:
160.87 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.61 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections